1994
United States Environmental Protection Agency
Washington, D.C. 20460
Office of Solid Waste and Emergency Response
September 21, 1994
Peter F. Downing, C.H.M.M.
Manager
Environmental, Health and Safety
Fidelity Chemical Products Corporation
470 Frelinghuysen Avenue
Newark, New Jersey 07114
Reference: Applicability of F006 Hazardous Waste Code to Nickel
Reclamation Process for Electroless Nickel Plating Spent Solutions
Dear Mr. Downing:
This responds to your letter dated November 5, 1993, requesting
an interpretation of the potential applicability of the hazardous
waste listings to your proposed process for reclaiming the nickel
in spent electroless nickel plating solutions. Because your proposed
process concerns a specific site, we have consulted with Mr. Jeffrey
A. Sterling of the New Jersey Metro Bureau of Water and Hazardous
Waste Enforcement and Mr. John Wilk of the Hazardous Waste Management
Division of Region II in preparing this response.
The application of the hazardous waste regulations discussed in
this letter is based on the information provided in your letter,
which we summarize here for convenience.
You propose to recycle the nickel in solution by reducing the
nickel ions with sodium hypophosphite through a controlled chemical
plate-out process, allowing gradual deposition of nickel on steel
wool. The nickel-plated steel wool will then be sent to a smelter
for further reclamation in a smelting operation. The batch process
will consist of l) adjusting the Ph and concentration of the sodium
hypophosphite reducing agent, 2) heating the solution to the optimum
reaction temperature, and 3) allowing the nickel to plate out
to a concentration of less than 10 ppm. The wastewater will then
be polished through activated carbon and sub-micron filters followed
by ion exchange and Ph adjustment prior to discharge to the local
POTW. Spent solutions not amenable to the plate-out process will
be precipitated to the metal hydroxide, followed by processing
through the identical polishing process described above.
Your letter requested verification of the following aspects of
your process with respect to the RCRA current regulations:
"1. Electroless nickel solution is not a hazardous waste
if it does not contain any listed waste (K,P,U,F) or wastes exhibiting
the characteristics of hazardous waste (D wastes).
2. Any treatment to reclaim or recycle the nickel from spent electroless
nickel solutions is not hazardous waste treatment subject to the
requirements of a hazardous waste treatment permit.
3. Regeneration of either the ion exchange resin or the activated
carbon does not require a hazardous waste treatment permit.
4. The sludge generated from the precipitation of the nickel as
a metal hydroxide is not a hazardous waste if it does not exceed
the TCLP parameters or exhibit any of the characteristics delineated
at 40 CFR Part 261, Subpart C, Characteristics of Hazardous Wastes.
5. The metal deposited on the steel wool is not a hazardous waste,
is a solid waste and is defined as scrap metal at 40 CFR 261.2(c)(6).
Our interpretation of the above based on current RCRA regulations
is as follows:
The spent electroless nickel solutions received from your
customers for the purpose of nickel metal reclamation are
not hazardous unless they have been mixed with or derived
from any listed waste(s) or exhibit any of the hazardous
waste characteristics under 40 CFR 261.20 through 261.24.
This determination is based on the fact that electroless
plating is specifically exempted from the scope of the F006
listing as defined by the Agency in the Interpretative Rule
which was published in the Federal Register on December 2,
1986 (51 FR 43350).
Unless the spent electroless nickel solutions are determined to
be characteristically hazardous, the proposed reclamation process
would not involve the treatment of hazardous waste. This also
applies to regeneration of either the ion exchange resin or the
activated carbon because the wastewater is not generated in an
electroplating process and also does not meet any other listing
description. Also, for the same reason, the sludge generated from
the precipitation of the nickel as a metal hydroxide is not a
hazardous waste if it does not exhibit any of the characteristics
identified in 40 CFR Part 261, Subpart C. (Although your letter
does not indicate how this sludge is to be managed, you should
be aware that a characteristic sludge that is destined for reclamation
is excluded from the definition of a solid waste. See 40 CFR 261.2(c)(3).
Note: The State of New Jersey does not have a similar exemption
at this time.)
Assuming the steel wool (on which the nickel has been plated)
does not exhibit the characteristic of a hazardous waste or is
not otherwise a hazardous waste because of the mixture-derived
from rule, the steel wool would not be a hazardous waste. If the
nickel-plated steel wool exhibits a characteristic of hazardous
waste, you raised the issue of whether it met the definition of
scrap metal (40 CFR 261.1(c)(6) and would be exempt when reclaimed
(40 CFR 261.6(a)(3)(iii)); because the definition of scrap metal
is based on a physical description of the material, the Agency
is unable to make a definitive determination. Such determinations
are case-specific and are typically made by the relevant State
unless the State is not authorized for RCRA in which case the
determination would be made by the relevant EPA Regional office.
Please contact the appropriate State officials if you need additional
assistance on this issue.
Please be aware that under Section 3006 of RCRA (42 U.S.C. Section
6926) individual States can be authorized to administer and enforce
their own hazardous waste programs in lieu of the Federal program.
When States are not authorized to administer their own program,
the appropriate EPA Regional office administers the program and
is the appropriate contact for any case-specific determinations.
Please also note that under Section 3009 of RCRA (42 U.S.C. Section
6929) States retain authority to promulgate regulatory requirements
that are more stringent than Federal regulatory requirements.
The Agency reserves the right to change this interpretation if
it finds new information which refutes either the facts or assumptions
on which this interpretation is based.
Thank you for your patience in this matter. If you have any further
questions, please contact Max Diaz of my staff at (202) 260-4786.
Sincerely yours,
William F. Brandes, Chief
Waste Identification Branch
cc: Waste Management Division
Directors, Regions I-X
John Wilk, Region II
Jeffrey A. Sterling, NJ DEQ
------------------------------------------------------------
Attachment
------------------------------------------------------------
FIDELITY CHEMICAL PRODUCTS CORPORATION
A DIVISION OF AURIC CORPORATION
470 FRELINGHUYSEN AVENUE
NEWARK, New Jersey 07114
November 5, 1993
U.S. Environmental Protection Agency
401 M Street, SW (OS-330)
Washington, D.C. 20460
Attn: Rick Brandes, Chief
Waste Identification Branch
Dear Mr. Brandes:
On Tuesday, October 26, 1993, I met with Dave Carver of your
staff regarding my letter dated August 4, 1993. This letter is
a follow-up to our meeting. As stated in my previous letter, we
are establishing a recycling program for our customers using electroless
nickel (EN) plating technology.
We propose to recycle the nickel in solution by reducing the nickel
ions with sodium hypophosphite through a controlled plate-out
procedure. This allows gradual deposition of nickel on steel wool
through chemical means. The nickel-plated steel wool will then
be sent to a smelter for use as a raw material in a smelting operation.
We anticipate the need to conduct an extensive auditing and quality
control program to ensure compliance with all applicable RCRA
standards. We will require a facility audit of our participating
customers to identify any potential problem areas which could
lead to the shipment to us of non-conforming electroless nickel
solution. This audit will include a tour of the plating areas,
waste management program, management procedures to prevent cross-contamination,
and sample collection. Samples will be submitted to us by the
customers for every drum to be returned. The samples will be analyzed
at our facility for heavy metals and plating characteristics,
and a composite will be sent to a NJ DEPE certified laboratory
for complete TCLP analyses with RCRA characteristics. The customer
has to complete a recyclable material profile which delineates
the characteristics of their spent EN solutions as well as certifying
that the samples submitted are representative of the material
to be shipped annually.
Once the material has been tested and determined to be acceptable,
the customer will ship the material to our facility, where we
will analyze the material and accept it only if it matches the
pre-shipment samples and meets all applicable TCLP parameters.
It is then pumped into our batch process, where the pH and concentration
of reducing agent are adjusted prior to recycling. The solution
is heated to the optimum working temperature and allowed to plate
until the concentration of nickel in solution is less than 10
ppm. It is then transferred to a process tank prior to polishing
through a carbon filter and sub-micron filtration, and finally
ion exchange for the removal of the remaining nickel from solution.
After final quality control and pH adjustment, the water is suitable
for discharge to our local POTW.
In the event that the spent EN solution meets RCRA characteristics
and TCLP parameters does not perform adequately in the plate-out
process, we will precipitate the nickel as a metal hydroxide.
Once precipitation is completed, it will be polished as above
to remove any residual nickel from solution.
Although many aspects of the process have been discussed with
Dave, I feel that it is necessary to verify some of the more critical
points:
1. Electroless nickel solution is not a hazardous waste if it
does not contain any listed waste (K,P,U,F) or wastes exhibiting
the characteristics of hazardous waste (D wastes).
2. Any treatment to reclaim or recycle the nickel from spent electroless
nickel solutions is not hazardous waste treatment subject to the
requirements of a hazardous waste treatment permit.
3. Regeneration of either the ion exchange resin or the carbon
does not require a hazardous waste treatment permit.
4. The sludge generated from the precipitation of the nickel as
a metal hydroxide is not a hazardous waste if it does not exceed
the TCLP parameters or exhibit any of the characteristics delineated
at 40 CFR Part 261, Subpart C, Characteristics of Hazardous Wastes.
5. The metal deposited on the steel wool is not a hazardous waste,
is a solid waste and is defined as scrape metal at 40CFR261.2(c)(6).
Please review my understanding of the key components of my meeting
with Dave Carver, as indicated in this letter, in writing at your
earliest convenience. Enclosed is a process schematic which may
assist you in reviewing the information contained in this letter.
If you have any questions or comments, please do not hesitate
to call me at 201-242-4110.
Very truly yours,
FIDELITY CHEMICAL PRODUCTS CORP.
PETER F. DOWNING C.H.M.M.
Manager
Environmental, Health and Safety
PFD/pd
cc:MB,PD
-----------------------------------------------------------
Enclosures
-----------------------------------------------------------
FIDELITY CHEMICAL PRODUCTS CORPORATION
A DIVISION OF AURIC CORPORATION
470 FRELINGHUYSEN AVENUE
NEWARK, New Jersey 07114
August 4, 1993
U.S. Environmental Protection Agency
401 M Street, SW (OS-330)
Washington, D.C. 20460
Attn: Rick Brandes, Chief
Waste Identification Branch
Dear Mr. Brandes:
On Thursday, July 29, 1993 I spoke to Mr. Dave Carver of your
office. This letter is to confirm my conversation with Dave regarding
classification of spent electroless nickel plating solutions.
We are a manufacturer of solutions for the metal finishing industry.
One of our primary product lines is electroless nickel (EN), a
technology which allows deposition of nickel on variety of substrates
without the need for an electrical current. As a service to our
customers, Fidelity Chemical Products has begun establishing a
recycling program for the nickel. Initial determinations have
been made and confirmed by Dave Carver that both the spent EN
solutions and the recycled nickel would not be considered a hazardous
waste by the US EPA.
The electroless nickel solution does not contain any listed hazardous
wastes. It passes for TCLP and RCRA characteristics. The solution
contains roughly 6 grams nickel per liter of solution, present
as nickel sulfate. The reducing agent in solution is sodium hypophosphite,
at a concentration of <5 percent.
Our process takes the EN solution, and continues plating the nickel
on steel wool, as our customers would. Rather then replenish the
nickel to the solution, however, we continue plating until the
concentration of nickel left in solution is below 10 ppm. We then
pass the solution through ion exchange to reduce the nickel concentration
to below our pre-treatment standards for discharge to our local
POTW. Prior to discharge, we filter any solids and carbon treat
the material, as we do with all of our effluent.
If we find that the nickel is not removable from solution by reduction,
we precipitate it as a metal hydroxide. This metal hydroxide also
meets TCLP requirements, and we would consider it to be a non-hazardous
waste material per RCRA standards.
In either event, the recycled material would be sent off site
to be smelted and recycled into various steel products. In this
manner, we feel that we can offer our customers a viable alternative
to conventional treatment and landfilling, while helping to protect
the environment.
Please respond to me in writing to confirm that the spent nickel
hydroxide are not hazardous wastes, and the process which I have
described herein would not be considered a "hazardous waste
treatment" method. I am very eager to get this recycling
program rolling, and would appreciate your response as soon as
possible.
If you have any questions, please call me at 201-242-4110.
Very truly yours,
PETER F. DOWNING, C.H.M.M.
Manager
Environmental, Health and Safety
---------------------------------------------------------
Enclosure
-----------------------------------------------------------
FIDELITY CHEMICAL PRODUCTS CORPORATION
A DIVISION OF AURIC CORPORATION
470 FRELINGHUYSEN AVENUE
NEWARK, New Jersey 07114
FAX MESSAGE
TO: Max Diaz - U.S. EPA
FROM: Peter F. Downing, C.H.M.M.
DATE: September 1, 1994
Total pages including cover sheet: 7
MESSAGE: Max
Per our discussion on 8/31/94, attached are the letters to NJ
DEP and their response regarding the spent EN recycling. Please call
me if you have any questions.
Thanks,
Pete
Please contact the sender at 201-242-4110 if any pages are missing or unclear.
-----------------------------------------------------------
Enclosure
-----------------------------------------------------------
State of New Jersey
DEPARTMENT OF ENVIRONMENTAL PROTECTION
DIVISION OF HAZARDOUS WASTE MANAGEMENT
Trenton, New Jersey 08625-0028
July 19, 1990
Mr. Maurice Bick, President
Fidelity Chemical Products Corporation
470 Frelinghuysen Avenue
Newark, New Jersey 07114
Re: Recycling of Electroless Nickel
Dear Mr. Bick:
This letter is in response to your July 5, 1990 letter to Kurt
Whitford discussing hazardous waste issues concerning the receipt
of spent electroless nickel plating solutions by your company.
As you stated in your letter, spent electroless nickel plating
solutions are not listed hazardous wastes in New Jersey (or Federally).
As such, these solutions could be hazardous in one or more of
three scenarios: 1) if mixed with wastes listed in N.J.A.C. 7:26-8.13,
8.14, or 8.20; 2) if displaying one or more of the RCRA characteristics
found in N.J.A.C. 7:26-8.9-8.12; or 3) designated as a hazardous
waste by the Department due to the presence of hazardous constituents
listed in N.J.A.C. 7:26-8.16.
Prior to accepting spent electroless nickel solutions from a company,
Fidelity Corporation should determine that no listed hazardous
wastes have been mixed with the solution. In addition to the auditing
and testing proposed, a total petroleum hydrocarbon (TPH) analysis
may be enlightening. Anytime TPH varies significantly from previous
batches, further investigation should be considered.
Although spent electroless nickel plating solution should not
fail any of the hazardous waste characteristics, routine evaluation
of batches should be performed, as outlined in your July 5, 1990
letter. Anytime a batch solution fails the criteria found in N.J.A.C.
7:26-8.9-8.12 the waste is hazardous and cannot be accepted by
your company without first obtaining a hazardous waste facility
permit.
Your letter states that spent solutions to be received by your
company will contain 4000-5000 ppm of nickel. At those concentrations,
the Department, when considering the factors listed in N.J.A.C.
7:26-8.6, would not consider the waste to be hazardous due to
the presence of nickel as a hazardous constituent.
If the spent nickel solutions are not hazardous waste, a RCRA
Part B permit and manifesting would not be required.
If you have any further questions, please contact Kurt Whitford
at (609) 292-8341.
Very truly yours,
Shirlee Schiffman, Chief
Bureau of Hazardous Waste
Regulation and Classification
-----------------------------------------------------------
Enclosure
-----------------------------------------------------------
FIDELITY CHEMICAL PRODUCTS CORPORATION
A DIVISION OF AURIC CORPORATION
470 FRELINGHUYSEN AVENUE
NEWARK, New Jersey 07114
July 5, 1990
N.J. Dept. of Environmental Protection
B H W R & C
CN 028
401 E. State Street, 5th Floor
Trenton, New Jersey 08625
Attn: Kurt W. Whitford
Bureau of Hazardous Waste
Planning and Classification
Re: Recycling of Electroless Nickel
Dear Mr. Whitford:
This letter is in follow-up to my and Al Ruffinis conversations
with you concerning the Federal and New Jersey state regulations
governing the recycling of electroless nickel wastes. As we indicated,
our firm is evaluating whether to offer such a recycling service
to customers who purchase electroless nickel from us. We would
be recycling the liquid nickel at our Newark, NJ facility. Some
precipitated nickel from our process would be manifested to WRC
Processing Resources or Inmetco. Some would be used internally.
The electroless nickel products to be reclaimed include 4855A,
4855BM, 4855CD, 4865A, 4865B, 4865C and similar formulations.
Customers will return spent materials to Fidelity where we will
then reclaim nickel from the solutions. The reclamation process
involves precipitating the nickel in tanks and filtration in a
filter press. The nickel sludge is then used internally or sold
to a reclamation facility which will recover the nickel. The received
nickel solutions are reduced from 4000-5000 pm to about 5 ppm
by us through precipitation. The remaining liquid is then put
through an ion exchange unit which will further reduce the nickel
content of the liquid to less than 0.1 ppm. The liquid is discharged
to the sewer in conformance with our Passaic Valley permit.
As we stated, our primary concern is whether such an activity
would require us to obtain a hazardous waste facility permit (commonly
known as a RCRA Part B Permit). We are also concerned as to whether
our customers must manifest the electroless nickel solutions to
be recycled that they are sending us.
You indicated there is a classification of material termed "spent
materials" which are considered to be solid wastes if they
are reclaimed. "A spent material is any material that has
been used and as a result of contamination can no longer serve
the purpose for which it was produced without processing."
You felt that waste electroless nickel falls into this category.
Having concluded that the waste is a solid waste, the next question
is whether or not the solid waste is a hazardous waste. Hazardous
wastes fall into two categories - listed and characteristic. Spent
material from electroless nickel plating is not listed as either
a non-specific waste source or a waste stream from a specific
source. The only specific nickel compounds which are listed hazardous
wastes as commercial or off specification products, are nickel
carbonyl and nickel cyanide. Based upon our description of our
material, you felt that electroless nickel is not a listed hazardous
waste.
You also explained that if spent electroless nickel is not a listed
waste, it may still be a hazardous waste if it is a characteristically
hazardous waste. A waste is characteristically hazardous if it
is ignitable, corrosive, reactive, or it exhibits the characteristic
of toxicity. These criteria are listed as follows:
Ignitable
A waste is ignitable if it meets one of the following criteria:
1) Flash point less than 140 degrees F.
2) Flammable solid.
3) Ignitable compressed gas.
4) Is an oxidizer as defined in 49 C.F.R. 173.151.
That section defines an oxidizer as a substance that readily yields
O2, to stimulate combustion of organic matter, such as chlorates,
permanganates and inorganic peroxides.
Corrosive
A waste is corrosive if it is
1) aqueous with a pH less than or equal to 2 or greater than or
equal to 12.5.
2) a liquid and corrodes steel at a rate greater than 0.25 inches
per year.
Reactive
A waste is reactive if it is:
1) is normally unstable.
2) reacts violently with water.
3) forms explosive mixtures with water.
4) generates toxic gases when mixed with water.
5) is a sulfide or cyanide bearing waste which canbgenerate toxic gases when exposed to pH conditions between 2 and 12.5.
6) is explosive or can be detonated.
Toxicity
A waste exhibits the characteristic of toxicity ("TC")
if an extract from a representative sample of the waste contains
one or more of listed contaminant at higher than listed levels.
Currently, the test procedure for toxicity is the Extraction Procedure
("EP") which looks at 14 contaminants. In September
of 1990 the EP toxicity test will be replaced by the Toxicity
Characteristic Leaching Procedure ("TCLP") and the list
of contaminants of concern will be expanded to 40.
Based upon our tests and knowledge of the electroless nickel,
we do not feel it exhibits the characteristics of ignitability,
corrosivity, reactivity or toxicity.
Al Ruffini and I also described our actual procedure for selecting
and monitoring customers to be included in this program. They
were as follows:
1) Customers would be selected one at a time and the customer
base for whom we would recycle electroless nickel would be built
up slowly.
2) A customer would be audited at their plant by us in order to
qualify for sending their nickel to us. We would look for strong
management, good environmental procedures and a well run, orderly
plant.
3) We would require a sample of their electroless nickel to be
sent to us before we accepted their first electroless nickel.
This sample would be sent to a State approved lot for EP Toxicity
Test. This would be for the first shipment only. We would, on
receipt of the first shipment, also send it to a NJ certified
lab for EP Toxicity Test.
4) On all future shipments from that customer, we would require
a certification that their shipment is in conformity with sample
previously submitted. We would test these future shipments for
EP Toxicity in our plant. If there is any questions regarding
a particular shipment, we would submit to a State certified laboratory
for their analysis.
5) Whenever and wherever TCLP toxicity testing becomes a requirement,
we will test under TCLP Toxicity rather than under EP Toxicity.
Based upon the above analysis and information which we gave to
you, you felt that electroless nickel was not a hazardous waste
by either Federal or State of NJ standards and that we would not
require a RCRA Part B Permit. You also felt that our customers
would not have to manifest the electroless nickel they were sending
to us unless their home state required it.
We feel that the above electroless nickel recycling project which
we have proposed would be good for Fidelity and good for the environment.
We would appreciate a letter from you indicating receipt of this
letter and that it basically describes our conversations with
you of June 27, 1990.
Very truly yours,
FIDELITY CHEMICAL PRODUCTS CORP.
MAURICE BICK
President